Self Help Documentation
Airflow
Controls
Cooling
Heating
Installation
Maintenance
Replacement Parts
Sensor
Start-Up

Controls Documentation
Alarms Troubleshooting
File Name
Document Purpose
Outlines the various alarms that i-Controller 2.0 revision 300 offer and how to troubleshoot them.
Outlines the various alarms that i-Controller revision 200 offer and how to troubleshoot them.
Balancing Modes
File Name
Document Purpose
Outlines how to utilize the air balancing mode in the i-Controller 2.0.
Outlines how to use the i-Controller 2.0 REV.300 Water Balance Mode for units with water source condensers.
Outlines how to utilize the air balancing mode in the i-Controller.
Outlines how to use the i-Controller REV.201 Water Balance Mode for units with water source condensers.
BMS Communication
File Name
Document Purpose
Outlines how to configure the BACnet communication settings for units with an i-Controller 2.0.
Overview of i-Controller 2.0 BACnet status parameters that can be mapped as “Outputs” to the BMS to provide real-time status of the Flo unit.
Overview of i-Controller 2.0 Modbus status parameters that can be mapped as “Outputs” to the BMS to provide real-time status of the Flo unit.
Outlines how to configure the Modbus communication settings for units with an i-Controller 2.0.
Outlines how to complete the i-Controller 2.0 to E2 integration.
Outlines how to configure the BACnet communication settings for units with an i-Controller REV.201.
Overview of i-Controller BACnet status parameters that can be mapped as “Outputs” to the BMS to provide real-time status of the Flo unit.
Outlines how to configure the Modbus communication settings for units with an i-Controller.
Overview of i-Controller Modbus status parameters that can be mapped as “Outputs” to the BMS to provide real-time status of the Flo unit.
Outlines how to complete the i-Controller to E2 integration.
Controls Update
File Name
Document Purpose
Outlines how to perform an i-Controller firmware/program update using a micro USB drive or a micro USB adapter.
Outlines how to perform an i-Controller 2.0 firmware/program update using a Windows 10 laptop.
Outlines how to perform an i-Controller 2.0 operating system update using a micro USB drive or a micro USB adapter.
Outlines how to perform an i-Controller firmware/program update using a USB drive.
Outlines how to perform an i-Controller firmware/program update using a Windows 10 laptop.
Navigation & Test Modes
File Name
Document Purpose
Outlines how to use the AAON touchscreen mini controller (part number V62130 & V62370).
Outlines how to navigate through the Danfoss MCX controller.
Outlines how to override compressors in an i-Controller 2.0 unit.
Outlines navigation for units with i-Controller 2.0, revision 300.
Outlines Visograph navigation for units with i-Controller revision 112.
Outlines Visograph navigation for units with i-Controller revision 200.
Outlines Visograph navigation for units with i-Controller revision 201.
Outlines how to connect to the Jace2 Controller as well as how to navigate the Jace2 Controller.
Outlines how to connect to the n-Controller (Novar controller) as well as how to navigate the n-Controller.
Sequence Of Operations
File Name
Document Purpose
Detailed sequence of operations for 31 to 70 ton MPU’s with i-Controller revision#200.
Detailed sequence of operations for 6 to 30 ton MPU’s with i-Controller revision#112.
Detailed sequence of operations for 6 to 30 ton MPU’s with i-Controller revision#200.
Detailed sequence of operations for 6 to 70 ton MPU’s with i-Controller revision#201.
Detailed sequence of operations for 6 to 70 ton MPU’s with i-Controller 2.0 revision#300.
Detailed sequence of operations for MPU’s with i-Controller 2.0 revision#300 that are using thermostat style controls.